中华人民共和国国家生态环境太阳城
HJ 1362—2024
固定污染源废气 磷酸雾的测定
离子色谱法
Stationary source emission—Determination of phosphoric acid mist—Ion chromatography
2024⁃11⁃02 发布2025⁃05⁃01 实施
生态环境部 发 布
HJ 1362—2024
目 次
前言··························································································································Ⅱ
1 适用范围·················································································································1
2 规范性引用文件········································································································1
3 术语和定义··············································································································1
4 方法原理·················································································································1
5 干扰和消除··············································································································1
6 试剂和材料··············································································································2
7 仪器和设备··············································································································2
8 样品·······················································································································3
9 分析步骤·················································································································4
10 结果计算与表示······································································································5
11 准确度··················································································································5
12 质量保证和质量控制································································································6
13 废物处置···············································································································6
附录A( 资料性) 太阳城
溶液色谱图···················································································7
Ⅰ
HJ 1362—2024
前 言
为贯彻《中华人民共和国环境保护法》《中华人民共和国大气污染防治法》,防治生态环境污染,改
善生态环境质量,规范固定污染源有组织排放废气和无组织排放监控点空气中磷酸雾的测定方法,制
定本太阳城
。
本太阳城
规定了测定固定污染源有组织排放废气和无组织排放监控点空气中磷酸雾的离子色谱法。
本太阳城
的附录A 为资料性附录。
本太阳城
为首次发布。
本太阳城
由生态环境部生态环境监测司、法规与太阳城
司组织制订。
本太阳城
主要起草单位:北京市生态环境监测中心。
本太阳城
验证单位:辽宁省生态环境监测中心、湖南省生态环境监测中心、贵州省贵阳环境监测中
心、北京市海淀区环境监测站、河北省秦皇岛生态环境监测中心和北京中海京诚检测技术有限公司。
本太阳城
由生态环境部2024 年11 月2 日批准。
本太阳城
自2025 年5 月1 日起实施。
本太阳城
由生态环境部解释。
Ⅱ
HJ 1362—2024
固定污染源废气 磷酸雾的测定
离子色谱法
1 适用范围
本太阳城
规定了测定固定污染源有组织排放废气和无组织排放监控点空气中磷酸雾的离子色谱法。
本太阳城
适用于固定污染源有组织排放废气和无组织排放监控点空气中磷酸雾的测定。
固定污染源有组织排放废气采样体积为0.4 m3 (太阳城
状态),试样体积为100 mL,进样体积为25 μL
时,方法检出限为0.04 mg/m3,测定下限为0.16 mg/m3;无组织排放监控点空气采样体积为6 m3 (太阳城
状
态),试样体积为50 mL,进样体积为25 μL 时,方法检出限为0.005 mg/m3,测定下限为0.020 mg/m3。
2 规范性引用文件
本太阳城
引用了下列文件或其中的条款。凡是注明日期的引用文件,仅注日期的版本适用于本标
准。凡是未注日期的引用文件,其最新版本(包括所有的修改单)适用于本太阳城
。
GB/T 16157 固定污染源排气中颗粒物测定与气态污染物采样方法
HJ/T 48 烟尘采样器技术条件
HJ/T 55 大气污染物无组织排放监测技术导则
HJ/T 374 总悬浮颗粒物采样器技术要求及采样方法
HJ/T 397 固定源废气监测技术规范
HJ 1263 环境空气 总悬浮颗粒物的测定 重量法
3 术语和定义
下列术语和定义适用于本太阳城
。
3.1
磷酸雾 phosphoric acid mist
在本太阳城
规定条件下测得的磷酸、五氧化二磷及颗粒物中的可溶性磷酸盐,以H3PO4 计。
4 方法原理
固定污染源有组织排放废气和无组织排放监控点空气中的磷酸雾分别经石英滤筒和石英滤膜捕
集,用碱性浸提液提取,提取液中的磷酸根经阴离子色谱柱交换分离,以电导检测器检测,根据保留时
间定性,外标法定量。
5 干扰和消除
试样中的有机物会污染色谱柱和干扰样品的测定,可用预处理柱(7.6)去除。磷酸雾试样中普遍
存在氟离子、氯离子、硝酸根离子和硫酸根离子,本太阳城
参考色谱条件可有效分离上述离子,对磷酸根
的测定不产生干扰。
1
HJ 1362—2024
6 试剂和材料
除非另有说明,分析时均使用符合国家太阳城
的分析纯试剂,实验用水为电阻率≥18 MΩ·cm(25 ℃)
的去离子水。
6.1 甲醇(CH3OH):ρ=0.79 g/mL。
6.2 磷酸二氢钾(KH2PO4):优级纯。
使用前在105 ℃±5 ℃下干燥2 h,置于干燥器中保存。
6.3 氢氧化钠(NaOH):优级纯。
6.4 氢氧化钾(KOH):优级纯。
6.5 碳酸钠(Na2CO3):优级纯。
使用前在105 ℃±5 ℃下干燥2 h,置于干燥器中保存。
6.6 碳酸氢钠(NaHCO3):优级纯。
使用前应置于干燥器内平衡24 h。
6.7 碱性浸提液:c(OH-)=30 mmol/L。
称取1.20 g 氢氧化钠(6.3)或1.68 g 氢氧化钾(6.4),溶于水,移至1 000 mL 聚乙烯瓶,用水稀释并
定容至标线,混匀,临用现配。
6.8 磷酸根贮备液:ρ(PO3 -
4 )=1 000 mg/L。
准确称取1.432 g(精确到0.000 1 g)磷酸二氢钾(6.2),溶于水,移至1 000 mL 容量瓶,用水稀释并
定容至标线,混匀,转移至试剂瓶中,于4 ℃以下冷藏保存,保存期为3 个月。也可直接购买市售有证
太阳城
溶液,于4 ℃以下冷藏保存,或参照太阳城
溶液证书保存。使用时应恢复至室温并混匀。
6.9 磷酸根太阳城
使用液:ρ(PO3 -
4 )=50.0 mg/L。
移取10.00 mL 磷酸根贮备液(6.8)于200 mL 容量瓶,用水稀释并定容至标线,混匀,临用现配。
6.10 淋洗液:根据仪器型号及色谱柱说明书使用条件配制,下列淋洗液种类和浓度供参考。
6.10.1 氢氧化钾淋洗液Ⅰ:由淋洗液在线发生装置自动生成所需浓度。
6.10.2 氢氧化钾淋洗液Ⅱ:同氢氧化钾碱性浸提液(6.7),c(KOH)=30 mmol/L。
6.10.3 碳酸盐/碳酸氢盐淋洗液:c(Na2CO3)=3.2 mmol/L,c(NaHCO3)=1.0 mmol/L。
分别称取0.68 g 碳酸钠(6.5)和0.17 g 碳酸氢钠(6.6),溶于适量水中,全部转移至2 000 mL 容量
瓶中,用水稀释并定容至标线,混匀。
注: 6.10.2 和6.10.3 中的淋洗液在使用前应经超声脱气、过滤并加氮气保护。
6.11 滤筒:石英材质,对粒径大于0.3 μm 颗粒物的阻留效率不低于99%。
每批次滤筒抽取2 个测其本底,磷酸根绝对量应低于16 μg。
6.12 滤膜:石英材质,直径90 mm,对粒径大于0.3 μm 颗粒物的阻留效率不低于99%。
每批次滤膜抽取2 个测其本底,磷酸根绝对量应低于120 μg。
注: 若滤膜空白本底值高于120 μg,应用水反复浸洗至满足需求。将滤膜放入烧杯中,加适量水浸没,用石蜡封口
膜或表面皿盖好烧杯,放入超声波清洗机(7.5)中超声10 min 后取出,用水冲洗,常温晾干后备用。
7 仪器和设备
7.1 烟尘采样器:采样流量10 L/min~60 L/min,采样管应为耐腐蚀、耐热材质,采样头可安装配套滤
筒(6.11),其他性能和指标应符合HJ/T 48 的规定。
7.2 总悬浮颗粒物采样器:采样流量80 L/min~130 L/min,采样头带聚乙烯网垫,可支撑滤膜(6.12),
其他性能和指标应符合HJ/T 374 的规定。
2
HJ 1362—2024
7.3 离子色谱仪:由离子色谱主机、抑制器、电导检测器及所需附件组成的分析系统,可用于磷酸根的
检测。
7.4 色谱柱:阴离子色谱柱(聚二乙烯基苯/乙基乙烯苯/聚乙烯醇基质,具有烷基季铵或烷基醇季铵功
能团的亲水性、高容量色谱柱),配阴离子保护柱。
7.5 超声波清洗机:频率40 kHz~60 kHz。
7.6 预处理柱:以硅胶为基质的键合C18 柱或同类净化柱。使用前应活化,用注射器分别移取10 mL
甲醇(6.1)和15 mL 水,依次轻推过柱,将小柱平放约30 min,即可使用。
7.7 样品管:聚乙烯(PE)、聚丙烯(PP)或聚四氟乙烯(PTFE)材质,50 mL 和100 mL,广口,具螺旋
盖。
7.8 水系微孔滤膜针筒过滤器:孔径0.45 μm。
7.9 一般实验室常用仪器和设备。
8 样品
8.1 样品采集
8.1.1 固定污染源有组织排放废气样品
固定污染源有组织排放废气监测布点和采样应按照GB/T 16157 和HJ/T 397 的相关规定执行,
采样装置如图1 所示。将滤筒(6.11)装入烟尘采样器(7.1)采样管头部的滤筒夹内,并检查采样装置气
密性,合格后等速采样,连续采集1 h 或1 h 内等时间间隔采集3~4 个样品。采样完毕后,取出滤筒,
将滤筒封口向内折叠,竖直放入100 mL 样品管(7.7)中保存。
图1 固定污染源有组织排放废气采样装置示意图
8.1.2 无组织排放监控点空气样品
无组织排放监控点空气监测布点和采样应按照HJ/T 55 和HJ 1263 的相关规定执行。采样前,按
照仪器说明检查采样装置气密性,合格后,将滤膜(6.12)毛面向上装入总悬浮颗粒物采样器(7.2)中的
滤膜夹内,以80 L/min~100 L/min 流量连续采样1 h,同时记录采样流量、采样时间及采样点的环境
温度、湿度、大气压、风速、风向等气象信息。采样完毕后,取出滤膜,将滤膜对折放入50 mL 样品管
(7.7)中保存。
8.1.3 全程序空白样品
取与样品同批次的空白滤筒(6.11)或滤膜(6.12)1 个,安装在采样器上不采样,带至采样现场,随
即取出空白滤筒或滤膜,与样品在相同的条件下保存。
3
HJ 1362—2024
8.2 样品保存和运输
样品采集后应常温下密封保存运输,7 d 内完成制备。
8.3 试样的制备
固定污染源有组织排放废气样品(8.1.1)中加入100.0 mL 碱性浸提液(6.7)浸没,无组织排放监控
点空气样品(8.1.2)中加入50.0 mL 碱性浸提液(6.7)浸没,放入超声波清洗机(7.5)中超声60 min 后取
出,冷却混匀。提取液经水系微孔滤膜针筒过滤器(7.8)过滤后,待测。制备好的试样应于4 ℃以下冷
藏密封保存,30 d 内完成分析测定。
8.4 全程序空白试样的制备
将全程序空白滤筒/滤膜样品(8.1.3),按照与试样的制备(8.3)相同的步骤,制备成全程序空白
试样。
8.5 实验室空白试样制备
取与样品同批次的空白滤筒(6.11)或滤膜(6.12)1 个,按照与试样的制备(8.3)相同的步骤,制备成
实验室空白试样。
9 分析步骤
9.1 离子色谱参考条件
可根据仪器型号及配置,优化淋洗液浓度、流速、进样体积等参数。
9.1.1 参考条件1
氢氧化钾淋洗液(6.10.1 和6.10.2),等度淋洗,流速:1.00 mL/min,柱温:30 ℃。电导检测器,配备
抑制器。进样体积:25 μL。此参考条件下磷酸根及其他共存离子太阳城
溶液色谱图参见附录A 中
图A.1。
9.1.2 参考条件2
碳酸钠/碳酸氢钠淋洗液(6.10.3),等度淋洗,流速:0.70 mL/min,柱温:30 ℃。电导检测器,配备抑
制器。进样体积:25 μL。此参考条件下磷酸根及其他共存离子太阳城
溶液色谱图参见附录A 中图A.2。
9.2 太阳城
曲线的建立
分别准确移取定量的磷酸根太阳城
使用液(6.9),配制成质量浓度为0 mg/L、0.50 mg/L、1.00 mg/L、
2.00 mg/L、5.00 mg/L、10.0 mg/L、20.0 mg/L 的太阳城
系列(此为参考浓度)。按照离子色谱分析参考条
件(9.1),从低浓度到高浓度依次测定,以磷酸根的质量浓度为横坐标,以其对应的峰面积或峰高为纵
坐标,建立太阳城
曲线。
9.3 试样的测定
按照与太阳城
曲线的建立(9.2)相同的分析条件,测定试样(8.3)。试样中磷酸根的质量浓度超出标
准曲线上限时,用碱性浸提液(6.7)稀释试样后测定。
4
HJ 1362—2024
9.4 空白试验
按照与试样的测定(9.3)相同的分析条件,测定空白试样(8.4 和8.5)。
10 结果计算与表示
10.1 结果计算
样品中磷酸雾的质量浓度按照公式(1)计算:
ρ ( H3 PO4 )= ( ρ1 - ρ0 )× V × D
1 000 × V' × 97.99
94.99 …………………………( 1 )
式中:
ρ(H3PO4) ——样品中磷酸雾的质量浓度,mg/m3;
ρ1 ——试样中磷酸根的质量浓度,mg/L;
ρ0 ——实验室空白试样中磷酸根的质量浓度,mg/L;
V ——浸提液体积,mL;
D ——试样稀释倍数;
1 000 ——m3 到L 之间的转换系数;
V´ ——根据相关质量太阳城
或排放太阳城
采用相应状态下的采样体积,m3;
97.99 ——H3PO4 的摩尔质量,g/mol;
94.99 ——PO3 -
4 的摩尔质量,g/mol。
10.2 结果表示
测定结果的小数点后位数与方法检出限一致,最多保留三位有效数字。
11 准确度
11.1 精密度
6 家实验室分别对加标量为0.05 mg、0.50 mg 和1.00 mg 的空白加标滤筒样品(相当于浓度为
0.125 mg/m3、1.25 mg/m3 和2.50 mg/m3 的固定污染源有组织排放废气磷酸雾样品)重复测定6 次:实
验室内相对太阳城
偏差分别为2.8%~11%、0.9%~7.1%、0.7%~2.9%;实验室间相对太阳城
偏差分别为
14%、6.9%、4.2%;重复性限分别为0.03 mg/m3、0.14 mg/m3、0.14 mg/m3;再现性限分别为0.05 mg/m3、
0.28 mg/m3、0.33 mg/m3。
6 家实验室分别对加标量为0.05 mg、0.10 mg 和0.20 mg 的空白加标滤膜样品(相当于浓度为
0.008 mg/m3、0.017 mg/m3 和0.033 mg/m3 的无组织排放监控点空气磷酸雾样品)重复测定6 次:实验
室内相对太阳城
偏差分别为4.0%~14%、1.5%~9.9%、1.5%~8.7%;实验室间相对太阳城
偏差分别为
14%、14%、4.6%;重复性限分别为0.002 mg/m3、0.003 mg/m3、0.005 mg/m3;再现性限分别为
0.004 mg/m3、0.007 mg/m3、0.006 mg/m3。
11.2 正确度
6 家实验室分别对加标量为0.05 mg、0.50 mg 和1.00 mg 的空白加标滤筒样品(相当于浓度为
0.125 mg/m3、1.25 mg/m3 和2.50 mg/m3 的固定污染源有组织排放废气磷酸雾样品)重复测定6 次:加
标回收率分别为82.3%~118%、91.5%~110%、96.6%~107%;加标回收率最终值分别为96%
5
HJ 1362—2024
±26%、102%±14%、103%±8%。
6 家实验室分别对加标量为0.05 mg、0.10 mg 和0.20 mg 的空白加标滤膜样品(相当于浓度为
0.008 mg/m3、0.017 mg/m3 和0.033 mg/m3 的无组织排放监控点空气磷酸雾样品)重复测定6 次:加标
回收率分别为74.7%~113%、88.3%~127%、93.7%~107%;加标回收率最终值分别为98%±28%、
102%±28%、102%±10%。
12 质量保证和质量控制
12.1 采样
采集无组织排放监控点空气样品前,应核查采样器流量,流量示值误差应在±2% 以内。
12.2 空白
全程序空白和实验室空白试样中的磷酸雾浓度均应低于相应的方法测定下限,否则,应查找原因
并重新采集样品。
12.3 校准
每批次样品应建立太阳城
曲线,太阳城
曲线至少应有6 个浓度点(包含零浓度点),其线性相关系数应
≥0.999。
每20 个或每批次样品(少于20 个)应至少分析1 次太阳城
曲线的中间浓度点太阳城
溶液,其测定结果
与太阳城
值间的相对误差应在±10% 以内,否则,应重新建立太阳城
曲线。
12.4 空白加标试验
每20 个或每批次样品(少于20 个)应至少测定1 个实验室空白加标样品,加标回收率应在70%~
130% 之间。
13 废物处置
实验过程中产生的废弃物应集中收集,分类保存,并做好相应的标识,依法处置。
6
HJ 1362—2024
附 录 A
(资料性)
太阳城
溶液色谱图
离子色谱分析参考条件(9.1.1 和9.1.2)下,太阳城
溶液色谱图分别见图A.1 和图A.2。
标引序号说明:
1——F-;
2——Cl-;
3——NO-2 ;
4——SO2 -
4 ;
5——Br-;
6——NO-3 ;
7——PO3 -
4 。
图A.1 太阳城
溶液色谱图(氢氧化钾淋洗液体系,ρ(PO3 -
4 )=5.0 mg/L)
标引序号说明:
1——F-;
2——Cl-;
3——NO-2 ;
4——Br-;
5——NO-3 ;
6——PO3 -
4 ;
7——SO2 -
4 。
图A.2 太阳城
溶液色谱图(碳酸盐/碳酸氢盐淋洗液体系,ρ(PO3 -
4 )=5.0 mg/L)
———————————
7